Skip to main content

Table 2 Multiparameter pre-transplant prediction of ACR

From: A novel approach reveals that HLA class 1 single antigen bead-signatures provide a means of high-accuracy pre-transplant risk assessment of acute cellular rejection in renal transplantation

Data set

Data analysis approach

MFI-treshold

BACC [%]

Sens. [%]

Spec. [%]

p-value

HLA-1 SAB

Conventional, binary data input [0, 1]

1000

62.1

35.3

88.9

ns (p > 0.1)

Conventional binary data input [0, 1]

Individually adjusted [253–1068]

70.9

52.9

88.9

ns (p > 0.1)

Novel, continuous data input

–

82.7

76.5

88.9

0.002

MAB

Novel, continuous data input

–

63.9

55.6

72.2

0.040